China China Factory Suppliers Built-in Air Conditioner QL-PSB-12 Drainage Pump Motor for Reliable HVAC Performance Manufacturer, Factory | Qiling
Inquiry
Form loading...
China Factory Suppliers Built-in Air Conditioner QL-PSB-12 Drainage Pump Motor for Reliable HVAC Performance
Hot Products

China Factory Suppliers Built-in Air Conditioner QL-PSB-12 Drainage Pump Motor for Reliable HVAC Performance

,

Introducing the Built-in Air Conditioner Motor PSB-12, a high-quality shaded pole motor specifically engineered for seamless integration into ceiling-mounted air conditioning systems. Manufactured in China, this motor is designed by trusted suppliers who prioritize operational reliability and energy efficiency. The PSB-12 motor ensures consistent performance in HVAC applications, making it ideal for environments that demand long-term durability. Utilizing established shaded pole technology and adhering to strict manufacturing standards, our factory produces this motor to guarantee stable operation under continuous duty conditions. Enhance your air conditioning systems with the PSB-12 motor, your dependable choice for quality and efficiency.

,

    Product Overview

    The Built-in Air Conditioner Motor PSB-12 is a shaded pole motor specifically designed for integration into ceiling-mounted air conditioning systems. Developed with emphasis on operational reliability and energy efficiency, this motor component provides consistent performance in HVAC equipment where long-term durability is required. The motor employs established shaded pole technology while incorporating precision manufacturing standards to deliver stable operation in continuous duty applications.

    Product Features

    This motor utilizes conventional shaded pole technology, offering straightforward operation with minimal maintenance needs. The construction emphasizes extended service life through robust material selection and optimized thermal management. The unit demonstrates reduced energy consumption during operation, supporting overall system efficiency. Acoustic emissions are maintained at low levels through precise dynamic balancing and electromagnetic optimization. Operating on standard AC220V/50Hz power supply, the motor ensures compatibility with common electrical infrastructures. Additional technical features include integrated thermal protection, corrosion-resistant treatment on critical components, and stable performance maintenance under variable operating conditions. The mechanical design facilitates straightforward integration into existing air conditioning assemblies while providing accessible interface connections for installation and servicing requirements.

    Technical Parameters

    Model QL-PSB-12
    Rated voltage AC220V/50Hz
    Rated current 0.070±0.02A
    Power 9W
    Rated speed ≥2400r/min
    Head 1.2m
    Noise 21(dB.30cm)
    Flow 375ML/min
    Capacity of water tank 375ML/min
    Operating ambient temperature 0-50°C
    Applicable air-conditioner power 12.5kw(50,000btu/hr)
    Starting voltage Starting normal at 80% of rated voltage
    The winding turn should be able to withstand the peak voltage AC1800V
    Insulation resistance DC500V≥100MΩ
    Dielectric strength Withstand AC 1800V for 1s without flashover or breakdown
    Steering Clockwise (facing the shaft end)

    Profile Dimension Diagram

    Product Application

    The PSB-12 built-in motor is primarily engineered for ceiling cassette air conditioning systems and concealed ceiling-mounted air handling units. It is suitable for commercial installations including office buildings, retail establishments, educational institutions, and healthcare facilities where reliable and quiet air movement is essential. The motor's durable construction supports extended operational requirements in hospitality environments, conference venues, and other spaces utilizing integrated climate control systems. The low-noise operation makes it appropriate for libraries, private offices, residential applications, and other noise-sensitive environments. The energy-efficient characteristics contribute to sustainable operation in continuously used spaces such as data centers, telecommunications equipment rooms, and medical facilities. The motor's standardized design also supports equipment maintenance and replacement projects in existing installations, ensuring performance consistency while maintaining compatibility with original system specifications.

    Frequently Asked Questions (FAQ)

    What is the primary application of the PSB-12 motor?
    The PSB-12 built-in motor is primarily engineered for ceiling cassette air conditioning systems and concealed ceiling-mounted air handling units in commercial, residential, and noise-sensitive environments.
    What are the main electrical requirements for this motor?
    The motor operates on a standard AC220V/50Hz power supply, with a rated power of 9W and a rated current of 0.070±0.02A.
    How noisy is the PSB-12 motor during operation?
    The motor features acoustic optimization and dynamic balancing, maintaining a low noise level of 21(dB.30cm), making it suitable for quiet environments like libraries and private offices.
    What safety and insulation protections are integrated?
    It features integrated thermal protection, corrosion-resistant treatment, an insulation resistance of DC500V≥100MΩ, and a dielectric strength that withstands AC 1800V for 1s without flashover or breakdown.
    Can this motor start under lower voltage conditions?
    Yes, the motor is designed to start normally at 80% of its rated voltage, ensuring reliable performance under variable power conditions.
    What is the flow rate and water tank capacity of the PSB-12?
    The motor has a rated flow rate of 375ML/min and a corresponding water tank capacity designed to handle 375ML/min.

    Leave Your Message